RUS | ENG

Thermometry system "ТСС-01" type
for monitoring temperature of grain storage

Full autonomy of temperature control system
Thermometry system TCC-01 does not require an additional power supply. All equipment and Cables supplied.

Thermometry system "TCC-01" type.

Digital grain temperature monitoring system TCC-01 type is intended for precision measurement and indication of grain mass temperature conditions in silos.

Application of TCC-01 thermometry system is optimal with small quantity of thermometry cables (not more 40 pcs in all silos). This quantity of thermometry cables is optimal for grain temperature monitoring at small elevators and granaries (farms etc.) .

Thermometry cable arrangement include special whole sheath. Inside protection sheath from high density polyethylene (HDPE) is incorporated metal carrying rope. In addition inside sheath temperature sensors are installed at regular intervals. The sensors are connected in parallel according to three-wire diagram.

Measuring values of grain temperature are indicated at liquid crystal display of digital indication unit, which connect to thermometry cables by special connector.

Digital indication unit use individual power supply from 4 pcs standard battery AA type that ensures safety and efficiency in operation:

  • full safe voltage;
  • there is no necessity of thermometry cable grounding for current shock protection;
  • explosion safety of thermometry system by using of low voltage supply;
  • absence of additional power supply cables;
  • high universality and applicability of AA battery;
  • possibility of use accumulators.

Single channel connection block unit is used for connection of digital indication unit to silos with one thermometry cable for temperature values receiving. Multiple channel connection block unit is used for connection of digital indication unit to silos with several thermometry cables.

Technical specifications of thermometry system TCC-01 type

Common

  • Temperature measurement range, °С:  -55…125
  • Max measurement error at range 0…85°С, °С ±0,5
  • Max measurement error at range -55…0°С, °С: ±2,0
  • Max measurement error at range 85…125°С, °С: ±2,0
  • Temperature measurement resolution, °С: 0,1
  • Service life, year: 12

Thermometry cable TP type

  • Length, m: 4…30;
  • Sensor quantity: 1…32;
  • Carrying rope buckling load, t: 2,0;
  • Power supply voltage, V: =5,0;
  • Current consumption max, mA: 60;
  • Environmental air operation temperature, °С: -40…125;
  • Max environmental humidity, %: 90;
  • Max vibration:
    • frequency, Hz:  ≤25;
    • amplitude, mm: ≤0,1;
  • Degree of protection: IP56;

 Indication and control unit TCC-IU/01 type

  • Power supply voltage, V: =4,0…9,0;
  • Type and quantity of supply batteries: 4 AA;
  • Current consumption max, mA: 130;
  • Environmental air operation temperature, °С: -30…45;
  • Max environmental humidity, %: 80;
  • Max vibration:
    •  frequency, Hz:  ≤25;
    • amplitude, mm: ≤0,1;
  • Degree of protection: IP54;

 Connection and power supply unit TCC-CU type

  • Power supply voltage, V: =5,0;
  • Environmental air operation temperature, °С: -40…80;
  • Max environmental humidity, %: 80;
  • Max vibration:
    • frequency, Hz:  ≤25;
    • amplitude, mm: ≤0,1;
  • Degree of protection: IP54;